Sensore di corrente a effetto Hall con trasduttore 30 ma

Tipo: Tipo di Sala
Tipo segnale uscita: Uscita analogica
Processo Produttivo: Integrati a semiconduttore
Materiale: Plastica
Precisione Grade: 0.5G
Applicazione: Alimentazione elettrica di commutazione

Products Details

Informazioni di Base.

Model No.
LD1
Grado IP
IP65
Certificazione
ISO
Su misura
Su misura
modello
B3-50atb3-100at B3-200A B3-300A
tensione di alimentazione
+-12 v, +-15 v.
larghezza di banda
@ -1 db 0~150 khz
isolamento galvanico
@ 50 hz, c.a., 1 min 3 kv
corrente nominale
10 ma~100 ma
Pacchetto di Trasporto
Green Plastic Film
Specifiche
CE, ISO, Rohs
Marchio
HEYI
Origine
Liushi, Yueqing, Zhejiang Province, China
Codice SA
8542390000
Capacità di Produzione
5000PCS/Month

Descrizione del Prodotto

LD1 series DC leakage current sensor is a series of new device developed according to principle of electromagnetic induction. Its low current is stable. It is highly insulating between its primary coil and secondary coil. This sensor is used to measure current of signal system, circuit, and leakage monitoring system, as well as to measure current difference.
30mA Transducer Hall Effect Current Sensor 
Electrical data (Ta=25ºC±5ºC )
Type LD1-10mA LD1-20mA LD1-30mA LD1-50mA LD1-100mA Unit
Rated current(Ipn) ±10 ±20 ±30 ±50 ±100 mA
Measure range(Ip) ±12 ±24 ±36 ±60 ±120 mA
Rated output @Ip=±Ipn                ±5±1% V
Supply voltage ±12,±15 V
Power Consumption  <25 mA
Offset voltage @Ip=0      ±50 mV
Offset drift @ -40~+85ºC     ≤±1.5 mV/ºC
Output drift @ -40~+85ºC    ≤±1 mV/ºC
Linearity @Ip=0-±Ipn      ≤1 %FS
Response time @50A/μS, 10%-90%     ≤50 μs
Galvanic isolation @ 50HZ,AC,1min     2.5 KV
  
Applications
·Variable speed drives
·Welding machine
·Battery supplied applications
·Uninterruptible Power Supplies (UPS)
·Electrochemical
30mA Transducer Hall Effect Current Sensor30mA Transducer Hall Effect Current Sensor
Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm.
3. Elucidation: 1:+15V 2:-15V 3:I0UT 4:NC
 
30mA Transducer Hall Effect Current Sensor30mA Transducer Hall Effect Current Sensor30mA Transducer Hall Effect Current Sensor

 
Directions for use

1. When the current will be measured goes through a sensor, the current will be measured at the output end.(Note: The false wiring may result in the damage of the sensor)
2.Custom design in the different rated input current and the output current are available.
 
Standards

·UL94-V0.
·EN60947-1:2004
·IEC60950-1:2001
·EN50178:1998
·SJ 20790-2000
 
General date
 
  Value Unit
Operating temperature(TA) -40 to +85 ºC
Storage temperature(TS) -40 to +125 ºC
Mass(approx) (M) 40 g
 
30mA Transducer Hall Effect Current Sensor30mA Transducer Hall Effect Current Sensor30mA Transducer Hall Effect Current Sensor30mA Transducer Hall Effect Current Sensor30mA Transducer Hall Effect Current Sensor30mA Transducer Hall Effect Current Sensor

Contattaci